Instructions-Parts
3A2096D
E-Flo® DC 4–Ball Piston Pumps
EN
Electric drive piston pumps for low to medium volume paint circulation applications.
For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See Technical Data, page 29, for
Maximum Working Pressure.
See page 3 for model part numbers and
approvals information.
PROVEN QUALITY. LEADING TECHNOLOGY.
Models
Models
The part number for your equipment is printed on the equipment identification label (L). The part number
includes digits from each of the following categories, depending on the configuration of your equipment.
E-Flo DC Pump
(EC)
Lower
Pump Size
(1, 2, 3, or 4)
Motor and
Controls
(1, 2, 3, or 4)
Pump Type
and Fittings
(1, 2, or 3)
Mounting Type
(0, 1, or 2)
EC
1 = 750 cc
2 = 1000 cc
3 = 1500 cc
4 = 2000 cc
1 = 1
Horsepower,
Basic
1 = Hard
Chrome,
NPT
0 = None
1 = Stand
2 = 1
Horsepower,
Advanced
2 = Hard
Chrome,
Tri-Clamp
3 = 2
Horsepower,
Basic
3 = Maxlife,
Tri-Clamp
2 = Wall Bracket
4 = 2
Horsepower,
Advanced
The following approvals apply to Basic models only (Part Nos. EC11xx, EC21xx, EC23xx, EC33xx, and
EC43xx).
NOTE:
See the E-Flo DC Motor manual for motor approvals information.
Related Manuals
Manual No.
3A2526
Description
Instructions-Parts
Manual, E-Flo DC Motor
3A2527
332013
Instructions-Parts
Manual, for E-Flo DC
Control Module Kit
Instructions-Parts
Manual, for Advanced
Display Control Module
(ADCM)
3A0539
Instructions-Parts
Manual, 4–Ball Lowers
3A2096D
3
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.
WARNING
FIRE AND EXPLOSION HAZARD
work area
Flammable fumes, such as solvent and paint fumes, in
prevent fire and explosion:
can ignite or explode. To help
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and
plastic drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable
fumes are present.
Grounding
• Ground all equipment in the work area. See
• Use only grounded hoses.
instructions.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless
they are antistatic or conductive.
Stop operation immediately
•
if static sparking occurs or you feel a shock, Do not use
equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
Static charge may build up on plastic parts during cleaning and could discharge and ignite
flammable vapors. To help prevent fire and explosion:
• Clean plastic parts only in well ventilated area.
• Do not clean with a dry cloth.
• Do not operate electrostatic guns in equipment work area.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can
cause electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before
servicing or installing equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes
and regulations.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid
severe burns:
• Do not touch hot fluid or equipment.
4
3A2096D
Warnings
WARNING
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing
Pressure Relief Procedure
equipment, follow the
and disconnect all power sources.
PRESSURIZED EQUIPMENT HAZARD
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.
Pressure Relief Procedure
• Follow the
when you stop spraying/dispensing and before
cleaning, checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
TOXIC FLUID OR FUMES
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin,
inhaled, or swallowed.
• Read MSDSs to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable
guidelines.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury,
including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes
but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent
manufacturer.
3A2096D
5
Warnings
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated
Technical Data
system component. See
in all equipment manuals.
Technical Data
• Use fluids and solvents that are compatible with equipment wetted parts. See
in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure.
Pressure Relief Procedure
• Turn off all equipment and follow the
when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment. Alterations or modifications may void agency approvals
and create safety hazards.
• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
6
3A2096D
Installation
Installation
Power Supply Requirements
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
National, State and Local safety and fire codes.
Location
See Table 1 for power supply requirements. The
system requires a dedicated circuit protected with a
circuit breaker.
When selecting the location for the equipment, keep
the following in mind:
• There must be sufficient space on all sides of
the equipment for installation, operator access,
maintenance, and air circulation.
Table 1 . Power Supply Specifications
Model
Voltage
Phase Hz
Current
• Ensure that the mounting surface and mounting
hardware are strong enough to support the weight
of the equipment, fluid, hoses, and stress caused
during operation.
EM0011 100–250
EM0012 Vac
1
50/60 20 A
EM0021 200–250
EM0022 Vac
1
50/60 20 A
• There must be a start/stop control (C) within easy
reach of the equipment. See Fig. 1.
Hazardous Area Cabling and Conduit
Requirements
Mount the Pump
Explosion Proof
Secure the stand to the floor with M19 (5/8 in.)
bolts which engage at least 152 mm (6 in.) into the
concrete floor to prevent the pump from tipping.
All electrical wiring in the hazardous area must be
encased in Class I, Division I, Group D approved
explosion-proof conduit. Follow all National, State,
and Local electric codes.
Level the pump as required, using shims.
A conduit seal (D) is required within 18 in. (457 mm)
of the motor for the US and Canada. See Fig. 3.
All cables must be rated at 70°C (158°F).
Flame Proof (ATEX)
Use appropriate conduit, connectors, and cable
glands rated for ATEX II 2 G. Follow all National,
State, and Local electric codes.
All cable glands and cables must be rated at 70°C
(158°F).
8
3A2096D
Installation
NON-HAZARDOUS AREA
HAZARDOUS AREA
Figure 1 Typical Installation
Key for Fig. 1
Key for Fig. 1
A
Electrical Supply (must be sealed conduit
E
F
Fluid Pressure Gauge
Fluid Shutoff Valve
approved for use in hazardous locations)
B
C
Fused Safety Switch, with lock
G
Pump Ground Wire. Two ground terminals
are provided if local code requires redundant
grounding connections.
Start/Stop Control (must be approved for
use in hazardous locations)
D
Explosion Proof Conduit Seal. Required
within 18 in. (457 mm) of the motor for the
US and Canada.
H
Fluid Drain Valve
3A2096D
9
Installation
Connect the Power Supply
3. Open the electrical compartment (S) on the
motor.
4. Bring the power wires into the electrical
compartment through the 3/4–14 npt(f) inlet port.
Connect the wires to the terminals, as shown.
Torque the terminal nuts to 25 in-lb (2.8 N•m)
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
National, State and Local safety and fire codes.
Do not over-torque.
maximum.
5. Close the electrical compartment. Torque the
cover screws to 15 ft-lb (20.3 N•m).
1. Ensure that the fused safety switch (B, Fig 2) is
shut off and locked out.
Figure 3 Connect the Power Wires
Notes for Fig. 3
Tighten all terminal nuts to 25 in-lb (2.8 N•m)
Figure 2 Locked Out Fused Safety Switch
Do not over-torque.
maximum.
2. See Fig. 3. Install a start/stop control (C) in the
electrical supply line (A), within easy reach of
the equipment. The start/stop control must be
approved for use in hazardous locations.
Tighten cover screws to 15 ft-lb (20.3 N•m).
A conduit seal (D) is required within 18
in. (457 mm) of the motor for the US and
Canada.
10
3A2096D
Installation
Grounding
This equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current.
Pump:
1.
See Fig. 4. Loosen the ground screw and
Figure 4 Ground Wire
attach a ground wire. Tighten the ground screw
securely. Connect the other end of the ground
wire to a true earth ground.
Fluid hoses:
2.
3.
Use only electrically conductive
hoses with a maximum of 500 ft. (150 m)
combined hose length to ensure grounding
continuity. Check the electrical resistance of
hoses. If total resistance to ground exceeds 25
megohms, replace hose immediately
NOTE:
Advanced models require installation
of the 24P822 Control Module. All pumps
connected to a common control module must be
grounded to the same ground point. Different
ground points (unequal potential) may cause
current to flow through component cables,
causing incorrect signals.
Fluid supply container:
Follow your local code.
3A2096D
11
Installation
Fluid Line Accessories
Install the following accessories in the order shown
in Fig. 1, using adapters as necessary. All fluid
lines and accessories must be rated to the maximum
working pressure of 400 psi (2.8 MPa, 28.0 bar).
Fluid drain valve (D):
relieve fluid pressure in the hose and circulation
system.
•
required in your system, to
Fluid pressure gauge (E):
•
•
for more precise
adjustment of the fluid pressure.
Fluid shutoff valve (F):
shuts off fluid flow.
Fill With Oil Before Using Equipment
See Fig. 5. Before using the equipment, open the fill
cap (P) and add Graco Part No. 16W645 ISO 220
silicone-free synthetic gear oil. Check the oil level in
the sight glass (K). Fill until the oil level is near the
halfway point of the sight glass. The oil capacity is
Figure 5 Sightglass and Oil Fill Cap
Flush Before Using Equipment
The pump fluid section was tested with lightweight
oil, which is left in the fluid passages to protect parts.
To avoid contaminating your fluid with oil, flush the
equipment with a compatible solvent before using
the equipment.
Do not overfill.
approximately 1.5 quarts (1.4 liters).
NOTE:
Two 1 quart (0.95 liter) bottles of oil are
supplied with the equipment.
Control Module Accessory
The Control Module Accessory is required with
Advanced E-Flo DC motors to provide the interface
for users to enter selections and view information
related to setup and operation. See the Control
Module Accessory Kit manual for installation and
operation information.
12
3A2096D
Operation
Operation
Startup
Pressure Relief Procedure
To operate the pump, follow the Startup instructions
for the Basic or Advanced motor in the Motor manual.
The Advanced E-Flo DC motors require installation of
the 24P822 Control Module Accessory Kit to provide
the interface for users to enter selections and view
information related to setup and operation. See the
Control Module Accessory Kit manual for installation
and operation information.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
Run the pump at a slow speed until the fluid lines are
primed and all air is forced out of the system.
Shutdown
1. Disengage the start/stop control (C). See Fig. 1.
2. Shut off and lock out the fused safety switch (B).
3. Open the fluid drain valve (D), having a waste
container ready to catch drainage. Leave open
until you are ready to pressurize system again.
3A2096D
13
Maintenance
Maintenance
Preventive Maintenance Schedule
Check Oil Level
The operating conditions of your particular system
determine how often maintenance is required.
Establish a preventive maintenance schedule by
recording when and what kind of maintenance is
needed, and then determine a regular schedule for
checking your system.
See Fig. 7. Check the oil level in the sight glass (K).
The oil level should be near the halfway point of the
sight glass when the unit is not running. If low, open
the fill cap (P) and add Graco Part No. 16W645 ISO
220 silicone-free synthetic gear oil as required. The
oil capacity is approximately 1.5 quarts (1.4 liters).
Do not overfill.
Change the Oil
NOTE:
Change the oil after a break-in period of
200,000–300,000 cycles. After the break-in period,
change the oil once a year.
1. See Fig. 6. Place a minimum 2 quart (1.9 liter)
container under the oil drain port. Remove the
oil drain plug (25). Allow all oil to drain from the
motor.
2. Reinstall the oil drain plug (25). Torque to 25–30
ft-lb (34–40 N•m).
3. See Fig. 7. Open the fill cap (P) and add Graco
Part No. 16W645 ISO 220 silicone-free synthetic
gear oil. Check the oil level in the sight glass (K).
Fill until the oil level is near the halfway point of
the sight glass. The oil capacity is approximately
Figure 7 Sightglass and Oil Fill Cap
Do not overfill.
1.5 quarts (1.4 liters).
4. Reinstall the fill cap.
Bearing Pre-Load
See Fig. 7. The bearing pre-loads (R) are factory
set and are not user adjustable. Do not adjust the
bearing pre-loads.
Flushing
• Flush before changing fluids, before fluid can dry
in the equipment, at the end of the day, before
storing, and before repairing equipment.
• Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
• Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
Figure 6 Oil Drain Plug
14
3A2096D
Troubleshooting
Troubleshooting
NOTE:
NOTE:
Check all possible remedies before disassembling the pump.
The LED on the motor will blink if an error is detected. See
Error Code Troubleshooting
in the motor
manual for further information.
Problem
Cause
Solution
Pump output low on both strokes. Inadequate power supply.
page 8 .
Exhausted fluid supply.
Refill and reprime pump.
Clear.
Clogged fluid outlet line, valves,
etc.
Worn piston packing.
Replace. See lower manual.
Pump output low on only one
stroke.
Held open or worn ball check
valves.
Check and repair. See lower
manual.
Worn piston packing.
Replace. See lower manual.
No output.
Improperly installed ball check
valves.
Check and repair. See lower
manual.
Pump operates erratically.
Exhausted fluid supply.
Refill and reprime pump.
Held open or worn ball check
valves.
Check and repair. See lower
manual.
Worn piston packing.
Replace. See lower manual.
Pump will not operate.
Inadequate power supply.
page 8 .
Exhausted fluid supply.
Refill and reprime pump.
Clear.
Clogged fluid outlet line, valves,
etc.
Fluid dried on piston rod.
Disassemble and clean pump.
See lower manual. In future, stop
pump at bottom of stroke.
3A2096D
15
Repair
Repair
Disassembly
Reassembly
NOTE:
If the coupling adapter (9) and tie rods
(6) have been disassembled from the motor, see
Reassemble the Coupling Adapter and Tie Rods to
1. See Fig. 8. Assemble the coupling nut (11) to
the piston rod (R).
1. Stop the pump at the bottom of its stroke.
2. Relieve the pressure. See the
2. Orient the lower (7) to the motor (3). Position the
lower on the tie rods (6). Lubricate the threads of
the tie rods. Screw the tie rod locknuts (8) onto
the tie rods. Tighten the locknuts and torque to
50-60 ft-lb (68-81 N•m).
3. Disconnect the hoses from the lower and plug
the ends to prevent fluid contamination.
4. Remove the 2-piece shield (12) by inserting a
screwdriver straight into the slot, and using it as
3. Insert the collars (10) into the coupling nut
(11). Tighten the coupling nut onto the coupling
adapter (9) and torque to 90–100 ft-lb (122–135
N•m).
Do
a lever to release the tab. Repeat for all tabs.
not
use the screwdriver to pry the shields apart.
4. Install the shields (12) by engaging the bottom
lips with the groove in the wet-cup cap. Snap the
two shields together.
5. Loosen the coupling nut (11) and remove the
collars (10). Remove the coupling nut from the
piston rod (R). Unscrew the locknuts (8) from the
tie rods (6). Separate the motor (3) and lower
(7). See Fig. 7.
6. To repair the lower, see the lower manual.
5. Flush and test the pump before reinstalling
it in the system. Connect hoses and flush
the pump. While it is pressurized, check for
smooth operation and leaks. Adjust or repair
as necessary before reinstalling in the system.
Reconnect the pump ground wire before
operating.
7. There are no user-serviceable parts in the
motor. Contact your Graco representative for
assistance.
16
3A2096D
Repair
Reassemble the Coupling Adapter and Tie Rods to the Motor
NOTE:
Use this procedure only if the coupling
2. Screw the coupling adapter (9) into the motor
adapter (9) and tie rods (6) have been disassembled
from the motor, to ensure proper alignment of the
motor shaft to the piston rod (R).
shaft and torque to 90–100 ft-lb (122–135 N•m).
3. Reassemble the pump to the motor, as explained
1. See Fig. 7. Screw the tie rods (6) into the motor
(3) and torque to 50-60 ft-lb (68-81 N•m).
Figure 8 Pump Assembly
Notes for Fig. 8
Torque to 50–60 ft-lb (68–81 N•m).
Torque to 90–100 ft-lb (122–135 N•m).
3A2096D
17
Parts
Ref
1
Part
Description
Qty
1
KIT, mounting bracket, pump; includes items
4 and 5; see manual 311619
STAND, floor
MOTOR; Basic or Advanced; see motor
manual; includes items 3a and 3b
LABEL, warning
OIL, gear, synthetic; ISO 220 silicone-free;
1 quart (0.95 liter); not shown
WASHER
2
3
1
1
3a▲
3b
16M130
16W645
1
2
4
5
6
7
8
9
10
11
12
15G924
108683
15H369
184128
184059
24F251
4
4
3
1
3
1
2
1
1
BOLT
ROD, tie
PUMP, displacement; see lower manual
NUT, lock, hex
ADAPTER
COLLAR, coupling
NUT, coupling
KIT, shield, coupler (includes 2 pieces)
▲ Replacement Danger and Warning labels, tags,
and cards are available at no cost.
3A2096D
19
Parts
Pump Matrix
Pump
Part No.
Pump
Series
Mounting
Bracket
(Ref 1)
Floor Stand Motor
Washer
(Ref 4)
Bolt
(Ref 5)
Lower
Pump
(Ref 7)
(Ref 2)
(Ref 3)
EC1110
EC1111
EC1112
EC1210
EC1211
EC1212
EC2110
EC2111
EC2112
EC2210
EC2211
EC2212
EC2310
EC2311
EC2312
EC2410
EC2411
EC2412
EC2320
EC2321
EC2322
EC2420
EC2421
EC2422
EC2330
EC2331
EC2332
EC2430
EC2431
EC2432
EC3310
EC3311
EC3312
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
EM0011
EM0011
EM0011
EM0012
EM0012
EM0012
EM0011
EM0011
EM0011
EM0012
EM0012
EM0012
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
24F413
24F413
24F413
24F413
24F413
24F413
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F424
24F426
24F426
24F426
24F426
24F426
24F426
24F427
24F427
24F427
24F427
24F427
24F427
24F432
24F432
24F432
255143
255143
256193
100133
100133
100101
100101
255143
255143
256193
256193
256193
256193
256193
256193
256193
256193
256193
256193
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
20
3A2096D
Parts
Pump
Part No.
Pump
Series
Mounting
Bracket
(Ref 1)
Floor Stand Motor
Washer
(Ref 4)
Bolt
(Ref 5)
Lower
(Ref 2)
(Ref 3)
Pump
(Ref 7)
EC3410
EC3411
EC3412
EC3320
EC3321
EC3322
EC3420
EC3421
EC3422
EC3330
EC3331
EC3332
EC3430
EC3431
EC3432
EC4310
EC4311
EC4312
EC4410
EC4411
EC4412
EC4320
EC4321
EC4322
EC4420
EC4421
EC4422
EC4330
EC4331
EC4332
EC4430
EC4431
EC4432
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
EM0021
EM0021
EM0021
EM0022
EM0022
EM0022
24F432
24F432
24F432
24F434
24F434
24F434
24F434
24F434
24F434
24F435
24F435
24F435
24F435
24F435
24F435
24F440
24F440
24F440
24F440
24F440
24F440
24F441
24F441
24F441
24F441
24F441
24F441
24F442
24F442
24F442
24F442
24F442
24F442
255143
255143
256193
100133
100133
100101
100101
255143
255143
256193
256193
256193
256193
256193
256193
256193
256193
256193
256193
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
255143
255143
100133
100133
100101
100101
3A2096D
21
Mounting Hole Patterns
Mounting Hole Patterns
Floor Stand
Dimension
Measurement
A
B
C
D
19.88 in. (505 mm)
14.50 in. (368 mm)
16.88 in. (429 mm)
17.00 in. (432 mm)
3A2096D
23
Mounting Hole Patterns
Pump Bracket
Dimension
Measurement
A
B
C
D
E
F
17.8 in. (451 mm)
14.5 in. (368 mm)
12.4 in. (314 mm)
9.0 in. (229 mm)
5.4 in. (137 mm)
7.4 in. (187 mm)
G
H
J
5.3 in. (133 mm)
2.0 in. (51 mm)
1.0 in. (25 mm)
K
L
1.6 in. (41 mm)
2.7 in. (69 mm)
M
N
P
4.4 in. (112 mm)
Four 0.562 in. (14 mm) diameter holes for mounting to stand
Four 0.438 in. (11 mm) diameter holes for mounting to wall
24
3A2096D
Performance Charts
Performance Charts
Key to Performance Charts
To find the fluid pressure (psi/bar/MPa) at a specific
fluid flow (gpm/lpm) and percentage of maximum
force:
NOTE:
The charts show the motor operating at
100%, 70%, and 40% of maximum force. These
values are approximately equivalent to an air motor
operating at 100, 70, and 40 psi.
1. Locate the desired fluid flow in the scale at the
bottom of the chart.
2. Follow the vertical line up to the intersection with
the selected percentage of maximum force (see
100% of maximum force
70% of maximum force
40% of maximum force
Key
the
below).
3. Follow left to the vertical scale to read the fluid
outlet pressure.
Table 2 . Models EC11xx and EC12xx (750 cc lower, 1 HP motor, 1400 lb maximum force)
CYCLES PER MINUTE
FLUID PRESSURE:
psi (bar, MPa)
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUID FLOW:
gpm (lpm)
3A2096D
25
Performance Charts
Table 3 . Models EC21xx and EC22xx (1000 cc lower, 1 HP motor, 1400 lb maximum force)
CYCLES PER MINUTE
FLUID PRESSURE:
psi (bar, MPa)
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUID FLOW:
gpm (lpm)
Table 4 . Models EC23xx and EC24xx (1000 cc lower, 2 HP motor, 2800 lb maximum force)
CYCLES PER MINUTE
FLUID PRESSURE:
psi (bar, MPa)
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUID FLOW:
gpm (lpm)
26
3A2096D
Performance Charts
Table 5 . Models EC33xx and EC34xx (1500 cc lower, 2 HP motor, 2800 lb maximum force)
CYCLES PER MINUTE
FLUID PRESSURE:
psi (bar, MPa)
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUID FLOW:
gpm (lpm)
Table 6 . Models EC43xx and EC44xx (2000 cc lower, 2 HP motor, 2800 lb maximum force)
CYCLES PER MINUTE
FLUID PRESSURE:
psi (bar, MPa)
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUID FLOW:
gpm (lpm)
3A2096D
27
Technical Data
Technical Data
E-Flo DC Pumps
U.S.
Metric
Maximum fluid working
pressure:
Models EC11xx and
EC12xx
Models EC21xx and
EC22xx
Models EC23xx and
EC24xx
Models EC33xx and
EC34xx
300 psi
200 psi
400 psi
300 psi
220 psi
2.07 MPa, 20.7 bar
1.38 MPa, 13.8 bar
2.76 MPa, 27.6 bar
2.07 MPa, 20.7 bar
1.52 MPa, 15.2 bar
Models EC43xx and
EC44xx
Maximum potential fluid
pressure:
Models ECx1xx and 218000/v (volume of lower in cc) = psi
ECx2xx
Models ECx3xx and 436000/v (volume of lower in cc) = psi
ECx4xx
1500/v (volume of lower in cc) = bar
3000/v (volume of lower in cc) = bar
Maximum continuous
cycle rate
20 cpm
Maximum Flow
Maximum flow is determined by the size of the pump lower.
Input voltage:
Models ECx1xx and
ECx2xx
Models ECx3xx and
ECx4xx
100–250 Vac, single phase, 50/60 Hz
200–250 Vac, single phase, 50/60 Hz
Input current
Power inlet port size
20 A maximum
3/4–14 npt(f)
Ambient temperature
range
Sound data
Oil capacity
Oil specification
Weight
32–104°F
1.5 quarts
0–40°C
Less than 70 dB(A)
1.4 liters
Graco Part No. 16W645 ISO 220 silicone-free synthetic gear oil
Pump package (motor, 1000cc lower,
stand, and tie rods): 220 lb
Pump package (motor, 1000cc lower,
stand, and tie rods): 99.8 kg
Fluid inlet size
Fluid outlet size
Wetted parts
1–1/2 npt(f)
1 npt(f)
See Lower Pump manual.
3A2096D
29
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its
name to be free from defects in material and workmanship on the date of sale to the original purchaser for
use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a
period of twelve months from the date of sale, repair or replace any part of the equipment determined
by Graco to be defective. This warranty applies only when the equipment is installed, operated and
maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction,
damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper
maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall
Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment
with structures, accessories, equipment or materials not supplied by Graco, or the improper design,
manufacture, installation, operation or maintenance of structures, accessories, equipment or materials
not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an
authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco
will repair or replace free of charge any defective parts. The equipment will be returned to the original
purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material
or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of
parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.
The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages
for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall
be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH
ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY
GRACO.
These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.),
are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable
assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from
Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other
goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or
otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents,
notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or
indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du
présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés,
donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures
concernées.
Graco Information
To place an order,
contact your Graco Distributor or call to identify the nearest distributor.
or Toll Free: Fax:
Phone:
612-623-6921
1-800-328-0211
612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco
reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English, MM 3A2096
Graco Headquarters:
International Offices:
Minneapolis
Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS, MN 55440-1441 • USA
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revised September 2014
|